Solarem energiam liberam et nitidam utere, industriam independentiae emendare ac energiam reducere sumptibus cum inverto hybrid - EU, perfecta solutione PV et altilium energiae administrationis repono.
Minimae generationis solaris princeps postulatio.
Maximum generationis solaris humilem postulant.
Minima generatio solaris, summa postulatio.
Maximilianus. Input Power (W)
7000Maximilianus. Input Voltage (V)
550MPPT Voltage Range (V)
125 - 500PV Terminal Type
MC4Satus Operatio Voltage (V)
125Maximilianus. Input Current (A)
2 * 14Maximilianus. Brevis Current (A)
2 * 17.5No. de MPPT
2No. of Stabat per MPPT
1DC Switch
IntegratedType altilium
LFP (Integrated BMS)Nominal Voltage (V)
48Operatio Voltage Range (V)
40 - 58Maximilianus. Crimen / fungi Power (W)
6000 / 6000Maximilianus. Crimen / Current fungi (A)
95/110Ratio altilium præcipe
Adaptatio auto-BMSNominal Apparens Power (VA)
6000Maximilianus. Apparens Power (VA)
6000Maximilianus. Active Power (W)
6000Maximilianus. Input Power (VA)
6000Eget Type
Unius PhaseNominal frequentia (Hz)
50/60Grid Voltage Range (V)
176 - 270Nominal Voltage (V)
230Frequentia Range (Hz)
45 - 55 / 55 - 65Maximilianus. Output Current (A)
26Maximilianus. Input Current (A)
26THDI (Rated power)
<3%PF
- 0.8 ~ + 0.8Switch Tempus
< 20 msMaximilianus. Active Power (W)
6000Nominal frequentia (Hz)
50/60Frequentia Accuracy (Hz)
± 0.1Nominal Voltage
230Maximilianus. Output Current (A)
26Voltage Accuracy
± 1%THDV (C%R Lond)
< 2%Output Parellel (Pcs)
6Plus Load
105%< Load ≤ 110%, 30S; 110%< Load ≤ 120%, 10S; 120%<Locus ≤ 150%, 0.02SMaximilianus. Efficientiam (BAT ad AC)
95%Maximilianus. Efficientia (PV ad AC)
97.6%CEC. Efficientia
97%Maximilianus. MPPT Efficiency
99.9%GFCI
√Anti-insula Praesidium
√PV String Input Reverse Polarity Protection
√Output super intentione Praesidium
√Output super Current Praesidium
√Output Short Praesidium
√Nulla Resistentia Deprehensio
√DC / AC Surge Protection
Typus III "Dimensio (W* D* H) (mm).
550 *200 * 515Net Pondus (kg)
25Temperature Range operating
-25 ~ 60℃ (45℃ cione);Relativum Umor
0~ 95% (non-constans)Maximilianus. Altitude (m) ;
> 2,000 DeratingElectronics Praesidium Degree
IP65Acta Type
Transformerless, Isolation (Bat to AC)Nocte Self Consummatio (W)
< 3Refrigerium
Naturalesonitus (dB)
< 35HMI
APP / LCDCOM
RS485 / CAN / WiFi / 4G (Libitum)salus
EN 62109-1/2,IEC / EN62477-1EMC
IEC/EN 61000-6-1, IEC/EN 61000-6-3Eget Code
South Africa NRS097-2-1:2017, UK G98, G99Warranty (Annorum)
5/10 (Libitum);Apicibus: Pro post-sales inquisitionis placere submittere informationes tuashic ".